【product description】
It is used to test the water absorption performance of various woven towel products using textile fibers as raw materials.
【working principle】
Absorption method: After the sample is washed, dried and adjusted for humidity, a certain amount of water flows through the sample within a specified time under standard conditions, and the percentage of the amount of water absorbed by the sample to the amount of raw water is determined.
【Related standards】
GB/T22799-2009 "Test Method for Water Absorption of Towel Products"
ASTM/D4772 Standard Test Method for Surface Water Absorption of Towel Fabric (Water Flow Test Method)
【technical parameter】
1. Glass funnel: 250ml
2. Flow cylinder: 100ml
3. Specimen angle: 60° to the horizontal
4. Sample holder diameter: medium 155mm
5. The distance between the water outlet end of the water pipe and the sample surface: 2mm-10mm
6. The inner side of the water pipe from the outer ring of the clamp ring: 28mm-32mm
7. Water tray size: 250X190X30mm (LXWXH)
8. Overall dimensions of the sample stand: 180*140*200mm
9. Instrument weight: 12KG